๐ฃ๐ผ๐๐ฒ๐ป๐๐ถ๐ผ๐๐๐ฎ๐/๐๐ฎ๐น๐๐ฎ๐ป๐ผ๐๐๐ฎ๐/๐๐ฅ๐/๐ญ๐ฅ๐ ๐ ๐ฎ๐ ๐ถ๐บ๐๐บ ๐๐๐ฟ๐ฟ๐ฒ๐ป๐: ยฑ๐ฎ๐ ๐๐๐ฟ๐ฟ๐ฒ๐ป๐ ๐ฟ๐ฎ๐ป๐ด๐ฒ: ยฑ๐ฎ๐ป๐ ~๐ฎ๐, ๐ญ๐ฌ ๐ฟ๐ฎ๐ป๐ด๐ฒ๐ ๐๐ฝ๐ฝ๐น๐ถ๐ฒ๐ฑ ๐ฃ๐ผ๐๐ฒ๐ป๐๐ถ๐ฎ๐น: ยฑ๐ญ๐ฌ๐ฉ(๐ฐ๐ฎ๐ป ๐ฏ๐ฒ ๐ฐ๐๐๐๐ผ๐บ๐ถ๐๐ฒ๐ฑ ๐๐ผ ยฑ๐ญ๐ฎ๐ฉ) ๐๐ผ๐บ๐ฝ๐น๐ถ๐ฎ๐ป๐ฐ๐ฒ ๐๐ผ๐น๐๐ฎ๐ด๐ฒ: ยฑ๐ฎ๐ญ๐ฉ ๐๐๐ถ๐น๐-๐ถ๐ป ๐๐๐ฆ/๐๐ฅ๐, ๐๐๐ฆ ๐ฟ๐ฎ๐ป๐ด๐ฒ: ๐ญ๐ฌฮผ๐๐~๐ญ๐ ๐๐ ๐ฃ๐ผ๐๐ฒ๐ป๐๐ถ๐ฎ๐น/๐ฐ๐๐ฟ๐ฟ๐ฒ๐ป๐ ๐ฎ๐ฐ๐ฐ๐๐ฟ๐ฎ๐ฐ๐: ๐ฌ.๐ญ% ๐ผ๐ณ ๐๐ต๐ฒ ๐ฟ๐ฎ๐ป๐ด๐ฒ ๐ฃ๐ผ๐๐ฒ๐ป๐๐ถ๐ฎ๐น ๐ฟ๐ฒ๐๐ผ๐น๐๐๐ถ๐ผ๐ป: ๐ญ๐ฌฮผ๐ฉ; ๐ฐ๐๐ฟ๐ฟ๐ฒ๐ป๐ ๐ฟ๐ฒ๐๐ผ๐น๐๐๐ถ๐ผ๐ป ๐ญ๐ฃ๐ฎ.
Brand: CORRTEST Instruments
Supply list for one unit of Potentiostat
1 x Instrument Host
1 Set Original CorrTestยฎ Software
1 x Power cable
1 x USB cable
2 x Electrode Cables
1 x Dummy cell (1kฮฉ||100ยตF)
1 x Userโs Manual
A. HARDWARE SPECIFICATION
1. Potentiostat/ Galvanostat/ EIS
โ Channel: Single
โ Zero resistance ammeter
โ Electrode system: supports 2, 3, 4 electrode system
โ Floating (isolated from earth) or earth-ground
โ Potential control range: ยฑ10 V
โ Current control range: ยฑ2 A (up to 5 A with current booster)
โ Potential control accuracy: 0.1% ร full range ยฑ1 mV
โ Current control accuracy: 0.1% ร full range
โ Potential resolution: 10 ฮผV (>100 Hz), 3 ฮผV (<10 Hz)
โ Current sensitivity: 1 pA
โ Rise time: <1 ฮผs (<10 mA), <10 ฮผs (<2 A)
โ Reference electrode input impedance: 10ยนยฒ ฮฉ || 20 pF
โ Current range: 2 nA ~ 2 A, 10 ranges
โ Compliance voltage: ยฑ21 V
โ Maximum current output: 2.0 A
โ CV and LSV scan rate: 0.001 mV ~ 10,000 V/s
โ CA and CC pulse width: 0.0001 ~ 65,000 s
โ Current increment during scan: 1 mA @ 1 A/ms
โ Potential increment during scan: 0.076 mV @ 1 V/ms
โ SWV frequency: 0.001 ~ 100 kHz
โ DPV and NPV pulse width: 0.0001 ~ 1000 s
โ AD data acquisition: 16 bit @ 1 MHz, 20 bit @ 1 kHz
โ DA Resolution: 16 bit, setup time: 1 ฮผs
โ Minimum potential increment in CV: 0.075 mV
โ IMP frequency: 10 ฮผHz ~ 1 MHz
โ Low-pass filters: covering 8-decade
โ Potential and current range: Automatic
2. Electrochemical Impedance Spectroscopy (EIS)
Signal generator
โ Frequency range: 10 ฮผHz ~ 1 MHz
โ Frequency accuracy: 0.005%
โ AC signal amplitude: 1 mV ~ 2500 mV
โ Signal resolution: 0.1 mV RMS
โ DC Bias: โ10 ~ +10 V
โ DDS Output impedance: 50 ฮฉ
โ Waveforms: sine wave, triangle wave, square wave
โ Wave distortion: <1%
โ Scan mode: logarithmic / linear, increase / decrease
Signal analyzer:
โ Minimum integral time: 10 ms or longest cycle time
โ Maximum integral time: 10โถ cycles or 10โต s
โ Measurement delay: 0 ~ 10โต s
DC offset compensation:
โ Potential compensation range: โ10 V ~ +10 V
โ Current compensation range: โ1 A ~ +1 A
โ Bandwidth: 8-decade frequency range, auto/manual setting
3. PC and O/S requirement
โ Communications Interface: USB 2.0/ Ethernet
โ Operating System: Windows 7/ Windows 8/ Windows 10/ Windows 11
4. Weight / Measurements
โ Net weight: 6.0kg
โ Gross weight: 10kg
โ Instrument size: 360 x 300 x160mm
โ Package measurements: 525 x 375x 225mm
B. SOFTWARE TECHNIQUES OF CS310M
1. Stable Polarization
โข Open Circuit Potential (OCP)
โข Potentiostatic (I-T curve)
โข Galvanostatic
โข Potentiodynamic (Tafel plot)
โข Galvanodynamic (DGP)
2. Transient Polarization
โข Multi Potential Steps
โข Multi Current Steps
โข Potential Stair-Step (VSTEP)
โข Galvanic Stair-Step (ISTEP)
3. Chrono Methods
โข Chronopotentiometry (CP)
โข Chronoamperametry (CA)
โข Chronocaulometry (CC)
4. Voltammetry
โข Linear Sweep Voltammetry (LSV)
โข Cylic Voltammetry (CV)
5. Electrochemical Impedance Spectroscopy (EIS)
โข EIS vs Frequency (IMP)
โข Galvanostatic EIS
โข EIS vs Potential (IMPE)(Mott-Schottky)
โข EIS vs Time (IMPT)
โข Galvanostatic EIS vs Time
6. Corrosion Measurement
โข Cyclic polarization curve (CPP)
โข Linear polarization curve (LPR)
โข Electrochemical Potentiokinetic Reactivation (EPR)
โข Electrochemical Noise (EN)
โข Zero resistance Ammeter (ZRA)
7. Battery test
โข Battery Charge and Discharge
โข Galvanostatic Charge and Discharge (GCD)
โข Potentiostatic Charging and Discharging (PCD)
โข Potentiostatic Intermittent Titration Technique (PITT)